9-354-A
Wrist grounding, as a safe method to derive electrostatic charge from people, consists of an adjustable wrist strap with woven silver-plated plastic fibers (close skin contact necessary) and a spiral cable, which connects the wristband with the earthing point via press buttons, electrically dissipative. The coiled cable has a safety resistance of 1 MOhm on each connection side and is approved for workplaces with a rated voltage up to 250 VAC. To ensure adequate insulation, the bracelet may only be stored in a dry place. Washing instructions for the bracelet: machine wash up to 30 ° C with soft washing powder, drying at low temperature (warm not hot), do not bleach. Avoid contact with acidic / alkaline solvents. ESD protection is retained for about 30 washing process.
Antistatic mat with a surface resistance of less than 10^8 Ohm (DIN 54345-1, DIN 53482), extremely tear-resistant, cold resistance -10 °C (DIN EN 1876-1), heat resistance +70 °C, flame-retardant (according to LOBA regulation, NFP 92507: M2), abrasion-resistant, antimicrobial.
EPA suitable. For working in electrostatically protected areas (ESD workplace / ESD protection zone).
ESD Handling Set consists of: